Circuit breaker China 6-10A (Pw-cir-br-3p-6-10a-ch)

Basic Info

Model NO.: LMM55H
Type: Circuit Breaker
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification: ISO9001-2000, CE
Pole No.: 1,1p+N,2,3,3p+N,4
Rated Current: 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63A
Rated Voltage: AC 230/400V
Energy Limiting Class: 3
Trademark: oem
Transport Package: Lmm55h
Specification: small
৳1,850.00
Circuit breaker ABB 6-10A (Pw-cir-br-3p-6-10a-abb)
ABB
circuit breaker
230V AC
10A
1
DIN
B
6kA
IP20
1...25mm2
-25...55°C
IEC/EN 60898, IEC/EN 60947-2
20000cycles
৳2,800.00
Circuit breaker China 32A (Pw-cir-br-3p-32a-ch)

Basic Info

Model NO.: DPN
Poles Number: 1
Type: Circuit Breaker
Function: Conventional Circuit Breaker
Professional Manufacture: 10 Year
Guarantee Period: 2 Year
Rated Current: 1A-63A
Voltage: 230V/400V
Capacity: 4ka, 6ka, 10ka
Charcteristic Curve: B, C, D
Attestation: CE, CB, ISO9001
Brand: Suntree
Model: Sdpn
Trademark: SUNTREE/OEM
Specification: 1a, 3a, 6a, 10a, 16a, 20a, 25a, 32a, 40a, 50a, 63a
Origin: Zhejiang China
HS Code: 8536200000
৳2,850.00
Circuit Breaker China 63A (Pw-cir-br-3p-63a-ch)

Basic Info

Model NO.: TGB1-63
Poles Number: 3
Type: Circuit Breaker
Function: Circuit-Breaker Failure Protection
Certification: ISO9001-2000, CE, CB, CCC
Brand Name: Tengen
Model Number: Dz47-63
Current: 5-63A
Voltage: 230/400V 400V
Tripping Way: Distribution and Power
Short Circuit Breaking Capacity: 10000A
Place of Origin: Zhejiang, China
Trademark: HENUO
Transport Package: International Standard Export Carton
Specification: CE CCC
Origin: Zhejiang China
HS Code: 853620000
৳3,200.00
Circuit breaker ABB B 32A (Pw-cir-br-3p-32a-abb)

Description

Line circuit breaker in accordance with DIN VDE 0641 part 11, 1-pole 230/400 V/AC.

Technical data 
Content1 pc(s)
Operating voltage230/400 Vac
CategoryCircuit breaker
Type32 A
Release characteristicsB/6kA
Nominal current32 A
Number of pins1

 

৳4,800.00
Circuit breaker ABB S403M-C63 Miniature 230/400 VAC, 63 A, 10 kA Interrupt (BB S403M-C63)

Product Specifications

Brand Name
ABB
MFR Part Number
S403M-C63
UPC
804325528115
UNSPSC
39121603
Item
Miniature Circuit Breaker
Type
Low Voltage
Series
Smissline
Voltage Rating
230/400 VAC
Amperage Rating
63 A
Frequency Rating
50/60 Hz
Interrupt Rating
10 kA
Number of Poles
3
Enclosure Type
IP20
Temperature Rating
-25 to 55 deg C
Dimensions
91 mm Height x 18 mm Width x 82 mm Depth
Standard/Approvals
IEC Approved, EN60898-1, EN60947-2
৳10,400.00
Circuit breaker ABB A1B 125A TMF 125-1250 3p F F (Pw-cir-br-3p-125a-abb)
  • EAN:
    8015644694012
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85362090

Dimensions

  • Product Net Width:
    76.2 mm
  • Product Net Height:
    130 mm
  • Product Net Depth / Length:
    60 mm
  • Product Net Weight:
    0.7 kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    136.5 mm
  • Package Level 1 Height:
    124 mm
  • Package Level 1 Depth / Length:
    110.5 mm
  • Package Level 1 Gross Weight:
    0.8 kg
  • Package Level 1 EAN:
    8015644694012

Additional Information

  • Electrical Durability:
    1500 cycle
  • Mechanical Durability:
    Nr. Operations 8500 cycle
  • Number of Poles:
    3
  • Opening Time:
    CB with SOR 15 ms
    CB with UVR 15 ms
  • Power Loss:
    at Rated Operating Conditions per Pole 11 W
  • Product Main Type:
    SACE FORMULA
  • Product Name:
    Moulded Case Circuit Breaker
  • Product Type:
    CB
  • Rated Current (In):
    Main Circuit 125 A
  • Rated Impulse Withstand Voltage (Uimp):
    6 kV
  • Rated Insulation Voltage (Ui):
    690 V
  • Rated Operational Voltage:
    550 V AC
    250 V DC
  • Rated Service Short-Circuit Breaking Capacity (Ics):
    (240 V AC) 12.5 kA
    (380 V AC) 9 kA
    (415 V AC) 5 kA
    (440 V AC) 5 kA
    (480 V AC) 5 kA
    (500 V AC) 2.5 kA
    (250 V DC) 2 Poles in Series 2.5 kA
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):
    (240 V AC) 25 kA
    (380 V AC) 18 kA
    (415 V AC) 18 kA
    (440 V AC) 15 kA
    (480 V AC) 10 kA
    (500 V AC) 5 kA
    (250 V DC) 5 kA
  • Rated Uninterrupted Current (Iu):
    125 A
  • Release Type:
    TM
  • Standards:
    IEC
  • Sub-type:
    A1
  • Terminal Connection Type:
    Front
  • Version:
    F

Certificates and Declarations (Document Number)

Classifications

  • ETIM 4:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 5:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 6:
    EC000228 - Power circuit-breaker for trafo/generator/installation prot.
  • ETIM 7:
    EC000228 - Power circuit-breaker for trafo/generator/installation protection
  • Object Classification Code:
    Q
  • WEEE Category:
    5. Small Equipment (No External Dimension More Than 50 cm)
৳11,400.00
Automatic Transfer Switch (ATS) ABB 125A (Pw-ats-125a-abb)
1. DESCRIPTION

Automatic Transfer Switch (ATS) is used which alternating current is no more than
660VAC,and the direct current is 250v.the rated frequency is 50 Hz. The ATS rated current
series is 40A, 63A, 125A, 160A, 200A, 250A, 400A, 630A, 800A, 1000A, 1250A.be divided
up two types with 3 poles and 4 poles. 40A, 63A, 125A, with 2poles.The ATS of 40~125A
is defined with ‘N’; 160~630A is defined with ‘T’; above 630A is defined with “M”.

2. SERVICE CONDITION

Air temperature
1) maximum temperature less than+40 Celcius2) minimum temperature is more than
-5Celcius
3) The daily maximum temperature less than +35Celcius atmospheric moisture relative
humidity no more than 50% when the maximum temperature is +40Celcius the monthly
maximum relative humidity is 90%can bear humidity from the sea .
Install elevation the elevation of the installation site l less than 2000 m, when used
in the higher sea level, should be consider air dielectric strength
and the cooling effect will be reduced.
Pollution degree the installation site of pollution degree is 3
Installation gradient the installation of ATS onto cabinet, the gradient not more than
(plus-minus) 25Celcius
Flashover distance the flashover distance is 80mm as the alternating current is 380v,
when 660v.the distance is 100mm
Order format:

3. OPERATING PRINCIPLE

when main power DC-BUS relay testing voltage signal, (such as loss of power or under
voltage) backup supply DC-BUS relaybegin action, at the same time connecting controlled
timing relay, after delay,connecting middle relay,supplying power for theRectifier
bridge.when driving solenoid coil, switches action of backup battery complete the circuit.
When the main power return normal The voltages relay action. After delay connecting
middle relay, supplying power for Rectifier bridge. The switch action when driving solenoid
Coil. Mains power restoration, backup battery terminal supply at the same time.
ATS CONTROL MODULE
SGQ_ ATS CONTROL MODULE ISSUE 2010-02-03 Version 1.0 Page 4 of 9

4. STRUCTURE AND INTENSITY

Structure
SGQ and ATS use solenoid coil driving, electric apparatus as linked at same time. The
major loop contact terminals are two static loads, one dynamic Load used “V” tape design.
The “M” type used UNICOIL direct current supply pulse operation, to avoid magnetic coil
under long Operations with live line work.”N” and “T” type used 2 coil direct current supply
pulse operation. The power switching in controller Main power AC220v without other
control power after electromagnetic driving, mechanical electrical linked under connecting
to avoid switching device for main and standby power sources communicated at the same
time so that aroused error.the switch has electric and Mechanism close instructions as
segregation of functions indicator.we also supply two normal open and two normal closed
passive secondary contacts for use of others

5. INTENSITY

SGQ and ATS as main double loop power supply and automatic transfer switch mainly
used for first order load which under state specified standards. it also adapted to
mansion,communication, coal mine and ship,industrial assembly, health and medicine,
military equipment and so on . The main switching power also can be network, auto
starting generator and storage battery, or set by customers. ATS switching time within
80ms.customers can delay according to practical .when the main power and standby
power supply at the same time, the main power preferred.
৳22,500.00
Molded Case Circuit Breakers ABB S4HD-3P-250A-NA (ABB S4HD-3P-250A)

S4HD-3P-250A-NA, ABB, SACE Isomax, type S4H-D, 3P, 3PH, 250A, 600V, 65kA@480V, UL listed, bolt-on, suitable for reverse feed applications, load side lug terminals, NA - No Overcurrent Protection, non-automatic switch, molded case circuit breakers

Part NumberS4HD-3P-250A-NA
ManufacturersABB
Sub-CategoryMolded Case
FamilySACE Isomax
TypeS4H-D
Phase3
Poles3
Voltage600
Amperage250
ConnectionBolt-On
ProtectionNon-Automatic
FunctionsNA - No Overcurrent Protection
AIC Rating65kA@480V
Frame SizeS4
৳28,700.00
প্রতি পৃষ্ঠায়      1 - 17 of 17